Logo

환자 모니터링 장비 도매: 검증된 공급업체

임상 환자 모니터, 심전도 시스템, SpO2 산소포화도 측정기의 주요 도매 공급업체를 살펴보세요. 모두 IEC 60601-1 및 ISO 13485 인증을 취득했습니다.

원하는 상품을 찾지 못하셨나요?

도매 조달을 시작할 준비가 되셨나요?

Towobo의 검증된 공급업체로부터 조달하세요.

공급업체에 문의 →

Patient monitoring device categories and specifications

Patient monitoring equipment spans several distinct product categories: multi-parameter monitors (bedside monitors) — the core ICU, HDU, and OR monitoring platform measuring ECG (1–12 lead), SpO2, NIBP (non-invasive blood pressure), temperature, and respiratory rate simultaneously; classified as portable (transport) or bedside (stationary with AC power); high-acuity models add IBP (invasive arterial/CVP), EtCO2 (end-tidal CO2), neuromuscular blockade monitoring, and BIS (bispectral index for anaesthesia depth); ECG machines — 12-lead resting ECG systems for cardiac diagnosis; standalone or connected to EMR; interpretive algorithms (Marquette 12SL, Philips DXL) provide AI-assisted diagnostic suggestions; Holter monitors for 24–48 hour ambulatory ECG recording; vital signs monitors — basic spot-check monitors measuring SpO2, NIBP, temperature, and pulse rate; used in general wards, clinics, and post-anaesthesia recovery; SpO2/pulse oximeters — bedside, handheld, and wrist-worn; Masimo SET technology is the clinical reference standard for motion-tolerant SpO2 measurement; fetal monitors (CTG machines) — cardiotocography systems for continuous fetal heart rate and uterine contraction monitoring during labour; required in all labour and delivery units; central monitoring stations — central nurse station displays aggregating data from 4–32 bedside monitors; patient data management systems (PDMS) integrating monitor data into EMR; and wearable/continuous monitoring — wireless sensors and telemetry systems for step-down units, subacute care, and increasingly for hospital-at-home programs. Critical specification parameters: display size (inches), number of waveform channels, battery life (hours), data storage capacity, connectivity (HL7, HL7 FHIR, DICOM for waveform archiving), and alarm management capabilities (IEC 60601-1-8 standard for alarm systems in medical equipment).

IEC 60601-1 and regulatory requirements for patient monitors

Patient monitoring equipment is regulated as an active medical device in all major markets. The key technical standard is IEC 60601-1 (Safety and essential performance of medical electrical equipment) — the essential baseline for CE MDR conformity assessment and FDA 510(k) clearance. IEC 60601-1 defines electrical safety requirements (protection against electric shock, energy hazards, mechanical hazards, temperature limits); essential performance requirements (monitoring functions that must be maintained during electrical disturbances); and the general framework for risk management under ISO 14971. Collateral and particular standards layer onto IEC 60601-1: IEC 60601-1-2 (EMC — electromagnetic compatibility for medical electrical equipment, essential in hospital RF-dense environments); IEC 60601-1-6 (usability engineering — aligning with IEC 62366 for human factors in medical device design); IEC 60601-1-8 (alarm systems — defining alarm prioritisation, alarm tone characteristics, alarm signal persistence, and alarm management requirements critical for clinical safety); and IEC 60601-2-27 (particular requirements for ECG monitoring equipment). ISO 80601-2-61 applies specifically to pulse oximeters (including motion tolerance and SpO2 accuracy requirements across different skin pigmentation levels). Under EU MDR 2017/745, multi-parameter monitors and ECG machines are typically classified as Class IIb active devices — requiring Notified Body certification. Under FDA, most patient monitors are Class II devices cleared through the 510(k) pathway; FDA classifies bedside multi-parameter monitors under 21 CFR 870.2300. For wholesale buyers: request IEC 60601-1 third-edition test reports from accredited test laboratories (NEMKO, Intertek, UL, CSA); verify the specific software version cleared in the 510(k); and for China-manufactured monitors, verify CE MDR NB certificate and EU Authorised Representative details.

Frequently asked questions

What is the difference between Masimo SET and conventional SpO2 technology?

Masimo SET (Signal Extraction Technology) is a patented pulse oximetry technology that separates arterial SpO2 signal from venous and motion noise — enabling accurate SpO2 readings during patient motion and low perfusion states where conventional oximetry produces inaccurate readings or dropouts. Masimo SET uses adaptive signal processing and adaptive noise cancellation with a two-photodetector sensor design. Clinical studies demonstrate significantly fewer false alarms and more accurate readings during movement and low perfusion versus conventional oximetry. Masimo SET is the clinical reference standard in ICU and perioperative monitoring — specified by major hospital groups globally. Nellcor (Medtronic) OxiMax is the principal competing technology; both are widely deployed. Generic Chinese pulse oximeters use conventional two-wavelength SpO2 algorithms without motion tolerance — acceptable for routine spot checks in stable patients but not for continuous monitoring in high-acuity settings.

What is a typical MOQ and price range for wholesale patient monitors from China?

Indicative wholesale prices from Chinese manufacturers (ex-works, standard configuration): Basic vital signs monitor (SpO2/NIBP/Temp, 5" display, Contec or similar): USD 150–400/unit at 50+ units. Mid-tier multi-parameter monitor (5-parameter, 10" display, Mindray MEC 1200 class): USD 800–2,000/unit. Mid-tier multi-parameter monitor with IBP and EtCO2 (Mindray iMEC or Biocare equivalent): USD 2,500–5,000/unit. Premium Mindray BeneVision N17 or equivalent ICU monitor: USD 5,000–12,000/unit. Comparable Philips IntelliVue or GE CARESCAPE monitors: USD 15,000–40,000/unit. MOQ: 1 unit for branded distributors; 10–50 units minimum for OEM/white-label arrangements. Lead time: 2–6 weeks for standard models from Chinese manufacturers; 8–16 weeks for custom configurations.

What connectivity standards should I specify for patient monitors?

For hospital-grade patient monitors intended for integration with EMR/HIS systems, specify: HL7 2.x or HL7 FHIR R4 interface for patient demographics and alarm/waveform data export to EMR; IHE PCD (Patient Care Device) profiles compliance — specifically PCD-01 (Communicate Clinical Observations from Care Device) for interoperability with hospital information systems; DICOM waveform export (DICOM Supplement 30) for ECG waveform archiving; IEEE 11073 (Medical/Health Device Communication) for device-to-gateway communication; and open API access for integration with clinical decision support systems. For central monitoring stations, verify compatibility with the specific bedside monitor models being procured — proprietary network protocols (Philips IntelliSpace, GE MUSE) typically only work within the same manufacturer ecosystem. Chinese monitor manufacturers increasingly support HL7 interfaces — verify implementation quality (not just claimed compliance) with a test interface before large-scale procurement.

검증된 도매 공급업체를 찾고 있습니까? 지금 바로 목록을 확인하세요.

공급업체에 문의

towobo의 공급업체

아직 이 상품을 등록한 공급업체가 없습니다. 아래에 필요한 상품을 알려 주시면 공급업체를 찾아 드리겠습니다.

전체 결과 보기 →

견적 요청

필요한 것을 알려주시면 여러 검증된 공급업체로부터 견적을 받으세요

왜 견적을 요청해야 하나요?

  • 여러 공급업체로부터 경쟁력 있는 가격을 받으세요
  • 요구 사항에 맞는 맞춤형 제안을 받으세요
  • 검증된 제조업체와 직접 연결하세요
  • 매칭 서비스로 소싱 시간을 절약하세요
국가 선택

정기적으로 구매하시나요?

무료 구매자 계정을 만들어 공급업체를 저장하고, 직접 메시지를 보내고, 보호된 결제를 이용하세요.

무료 계정 만들기

관련 페이지

오늘부터 조달 시작하기

검증된 공급업체를 비교하고, 재고를 확인하고, 직접 연결하세요 — 모두 한 곳에서.

공급업체에 문의 →